14 Fonctionnement
Horizontal Termination with Three 90° Elbows (all vertical)
L’embout doit obligatoirement se trouver dans la zone hachurée du tableau. Utiliser les positions indiquées pour les restricteurs et le diffuseur.
21' max (6.4m)
15 feet (4.5m)
10' min (3m)
5 feet (1.5m)
21' max (6.4m)
Restrictor
Position # 5
Restrictor
Position # 1
NOTE:
Restrictor positions are based upon lab tests. The ideal restrictor position may vary slightly, especially when the termination is near a demarkation line.
15 feet (4.5m)
10' min (3m)
NOTE:
Horizontal sections require a 1/4" (0.250mm) rise every 12" (305mm) of travel.
5 feet (1.5m)
0 feet 0 feet
These are vertical elbows.
This is a horizontal elbow -
NOT ALLOWED FOR THIS
VENT CONFIGURATION
© Travis Industries 4100326 100-01250_000
/